19Pc Dental New Broken Screws Remove Kits Claw Drill Guide Reverse Drill Screws. Universal Implant Screw Remove Kits. H2.4 Internal Guide Hex. H2.5 Internal Guide Hex.
O3.1 Internal Guide Hex. Upgraded model of Neobiotech SR Kit, with 0.8 revserse drill and screw remover (remove M1.4 & M1.6 screw). This kit can remove almost all the implant screw with different size in the market. This kit kit is composed of various tools designed for quick and safe removal of fractured screws.
(1,200 RPM without irrigation). Remove a fractured screw without damaging or repositioning the fixture. Quick and easy procedure completed in 3 minutes. Capable to remove fractured screws from different implant systems. Stuck screws can be removed with a ratchet. This is a surgical tool that removes a screw that has become fractured inside the Fixture. After selecting the size that is appropriate for the size of the screw that is to be removed, it must be used by connecting a guide to the Fixture (Conical/Internal/External Guide). Then it is connected to the Shank Driver, and the fractured screw can be removed by rotating by hand in the reverse direction. If the fractured screw cannot be removed using the Claw, it must be removed using the Reverse Drill and the Screw Remover. Products Name Fractured Screw size. Claw Drill M1.6M1.6.Claw Drill M1.8M1.8. Claw Drill M2.0M2.0. This is a tool that creates a hole on the fractured face of the Screw that will be used by the Screw Remover.
After selecting the appropriate Reverse Drill for the size of the screw that needs to be removed, it must be used by connecting a guide for the fi xture (Perfect/ Conical/Internal/External Guide). The depth of the drill can be adjusted from 1 mm to 3 mm, because the Drill body has markings. Although different manufacturers produce different sizes of abutment screws, except in rare cases, typically they utilize screws of Size M1.6, M1.8, M2.0, or M2.5.'M' stands for a metric screw.The number indicates the external size of the screw. For example, "M1.6 Screw" indicates that it is a metric screw the external diameter ofWhich is 1.6 mm. 0.8M1.4 /M1.6.
This is a device that removes a fractured screw. Insert a Screw Remover that is appropriate for the size of the hole that has been formed using the Reverse Drill and rotate at a low speed (at or below 80 rpm) in the reverse direction.
The Screw Remover was designed in a tapered shape so as to increase, as it turns, the amount of friction, which is necessary to loosen the Screw. 0.8M1.4 /M1.6. This is a surgical tool that was designed to be connected to the Screw Remover to allow the use of the hand, Torque Wrench, or Ratchet. Perfect Guide & PG Hand Driver. The Perfect Guide acts as a Guide for the Reverse Drill. It is used when the screw is fractured at the lower part of the female screw inside the Fixture. It is connected to PG Hand Driver and is directly applied to the Fixture female Screw. The Perfect Guide can be safely used because it has a stop structure inside that prevents the Reverse Drill from drilling more than 2 mm.They act as the Guide when using the Reverse Drill. They are used when the Perfect Guide cannot be used, or if the screw was fractured at a location deeper than 2 mm into the lower part of the female screw inside the Fixture. The Guide appropriate for connecting to the Fixture must be selected. This can be easily affixed to the Fixture by connecting it to the 3.5 Double Hex part of the Conical, Internal, or External Guide. The sale of this item may be subject to regulation by the U.
Food and Drug Administration and state and local regulatory agencies. If the item is subject to. City State: Zhengzhou, Henan China.