Drill Driver Tool

US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit


US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit
US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit

US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit    US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit

US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit. Universal Torque Ratchet & Drivers. Torque Ratchet 15-70Ncm (15, 30, 45, 70Ncm). One piece construction, well polished.

Totally 16 drivers, compatible with different implant system. Osstem, 3I, Megagen, Neobiotech, Datsing.

Dentium, Dentis, BEGO, Astra, KJ MEDITECH, Zimmer, MIS, Cortex, Adin, Biohorizon, Alpha Bio Tech. Used to fix or separate upper structures in implant surgery.

Accessible to the molar area which is hard to implant easily with wrench. Compete with Surgident SD-TORQUE With 6 drivers. Universal torque wrench, recommended with any type of implants. Perfect control of torque thanks to 7 torques values. Automatic declutching for optimum security. Only 135 gr for a better freedom of movement. Optimized access in mouth thanks to the micro-head. 100° angulated micro-head for easy access in mouth (posterior areas).

One piece design with smooth surface to limit bacterial retention. The success of the implant treatment depends on the precise tightening of the parts placed directly on the implant. A pre-stressed tightening of the screw will help avoid any risk of screw loosening. Also, high tightening torques may lead to screw fracture.

A calibrated tightening can only be guaranteed through the use of a precision instrument offering a torque control system. The dynamometrical manual wrench Torq Control® has been specially designed to meet those requirements.

6 hand drivers with autoclave holder. Stainless steel screw drivers for dental implant. With different color, easy to indentify the model. Driver 1.0 Hex Ankylos (Green). Driver 1.2 Hex Osstem (Black) fit Osstem, 3I, Megagen, Neobiotech, Datsing.

Driver 1.27 Hex Dentium (Purple) fit Dentium, Dentis, BEGO, Astra, KJ MEDITECH, Zimmer, MIS, Cortex, Adin, Biohorizon, Alpha Bio Tech. Driver 1.4 Hex ICX (Golden). Driver R165 ITI (Blue) fit ITI DIO.

Simple & easy access to sinus cavity. Broad exposure of bony walls with special instruments DASK is an advanced sinus lifting kit. The drills are internally irrigated, designed to create hydraulic pressure that protects the sinus membrane when drilling.

The DASK kit contains 3 drills for the lateral approach, 3 drills for the crystal approach, 4 drill stoppers and 4 sinus hand instruments. The drills are internally irrigated to create an umbrella effect to reduce the risk of a potential perforation to the sinus.

DASK Drill #1 XRT 332035. Crestal Approac DASK Drill #2 XRT 372035 DASK Drill #3. DASK Drill #4 XRT 064025 Lateral Approach DASK Drill #5 XRT 084025 DASK Drill #6. DASK Drill #15 : Drill speed 800 to 1,200 rpm, 3045Ncm with internal irrigation DASK Drill #6 : Drill speed 800 to 1,200 rpm, 3045Ncm with external irrigation Stopper For XRT332035, XRT372035, XED331035D Drilling DepthLArt. XFDST 02 Sinus Elevation Instrument Art.

NO XSE1L XSE2L XSE3L XSE4L. Screw Remover Kit is a surgical tool developed in order safely and quickly to remove screws that have become fractured inside an implanted Fixture for various reasons. After removing the Screw, a new Abutment may be connected to the Fixture. Remove Fractured Screw, Screw Remover! No Worries About Fractured Screw.

This is a surgical tool that removes a screw that has become fractured inside the Fixture. After selecting the size that is appropriate for the size of the screw that is to be removed, it must be used by connecting a guide to the Fixture (Conical/Internal/External Guide). Then it is connected to the Shank Driver, and the fractured screw can be removed by rotating by hand in the reverse direction.

If the fractured screw cannot be removed using the Claw, it must be removed using the Reverse Drill and the Screw Remover. This is a tool that creates a hole on the fractured face of the Screw that will be used by. After selecting the appropriate Reverse Drill for the size of the screw that needs to be.

Removed, it must be used by connecting a guide for the fi xture Perfect/ Conical/Internal/. The depth of the drill can be adjusted from 1 mm to 3 mm, because. The Drill body has markings.

The removal of an M1.6 size Screw Should utilize the Claw. Although diff erent manufacturers produce diff erent sizes of abutment screws, except in. Rare cases, typically they utilize screws of Size M1.6, M1.8, M2.0, or M2.5.'M' stands for a metric screw.

The number indicates the external size of the screw. Example, "M1.6 Screw" indicates that it is a metric screw the external diameter of Wh. This is a device that removes a fractured screw.

Insert a Screw Remover that is. Appropriate for the size of the hole that has been formed using the Reverse Drill and. Rotate at a low speed (at or below 80 rpm) in the reverse direction.

The Screw Remover was designed in a tapered shape so as to increase, as it turns, the. Amount of friction, which is necessary to loosen the Screw.

This is a surgical tool that was designed to be connected to the Screw Remover to allow the use of the hand, Torque Wrench, or Ratchet. Perfect Guide & PG Hand Driver. The Perfect Guide acts as a Guide for the Reverse Drill. It is used when the screw is fractured at the lower part of the female screw inside the Fixture. It is connected to PG Hand Driver and is directly applied to the Fixture female Screw.

The Perfect Guide can be safely used because it has a stop structure inside that prevents the Reverse Drill from drilling more than 2 mm. They act as the Guide when using the Reverse Drill. They are used when the Perfect Guide cannot be used, or if the screw was fractured at a location deeper than 2 mm into the lower part of the female screw inside the Fixture. The Guide appropriate for connecting to the Fixture must be selected.

This can be easily affixed to the Fixture by connecting it to the 3.5 Double Hex part of the. Conical, Internal, or External Guide.

Fixture & Screw Removal Kit. The usage of the SOS implant remover kit is easy and convenient just insert a remover tip into the implant until it is tight then make use of the hand adaptor or remover wrench to extract the implant from the socket. Capable of removal and replacement of implants in ill-positioned placement cases.

It helps to remove broken screws without damaging the implant. A perfect solution with the best results. All is done with minimal trauma to the patient and without any surgical interference. Both Osseo integrated implants and fractured implants are simply removed.

No bone damage or trauma to patients. No need to use a trephine drill.

Applicable to any type of implant with a screw hole. Capable to remove and replace the implant in an ill-positioned implant placement case. Helps to remove broken screws without damaging the implant. Fit virtually any implant system external hex, internal hex, conical connection, and more. Removes failed implants without compromising surrounding bone or damaging neighboring structures. Screw remove guide sub non-hex 22N. Screw remove guide sub non-hex 16N. This is the tool to take out the broken screw by turning in reverse way.

This tool is for taking out broken screw through picking up. Instruments to guarantee the screw remove drill can be stable working in the center of broken screw. To take out useless fixture by bone loss or broken, use this by locking in reverse way.

This is the tool after making the hole like slot shape and turn in reverse way to take out. Use this attaching with the fixture remove and the cover screw remove for when you put your fingers to screw.


US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit    US Implant Torque Ratchet Drivers / Sinus Lift DASK / Fixture Screw Removal Kit